Building Showcase

Good OTTV Envelope System

Roof

  • 50mm light weight concrete topping

  • 50mm heavy weight concrete with dry aggregate

  • 9.5mm built-up topping

  • 50mm expanded polystyrene insulation

  • 150mm heavy weight concrete with undried aggregate

  • 100mm or more air layer to roof

  • 19mm acoustic tile

External Wall

  • 6mm tinted curtain wall glass panel

  • 19mm air layer between glass

Internal Wall

  • 100mm light weight concrete block

  • 20mm plaster cement with sand aggregate (on both sides of concrete block)

  • 13mm gypsum board (2 layers)

  • 19-100mm air layer between gypsum board

Ceiling/ Floor

  • Concrete floor construction with U-value of 0.233